|| Main Page || Company
Profile || Offer || Products || Cooperation offer
|| Validation || Email ||
Leaflets/specifications: Hygromethers,
Thermometers (Dataloggers), Calibrators, Memory
readers Temperature Probes, Humidity & temperature probes, Manometers,
Temperature Loggers
Microprocessor based
Thermometer Model KRT 406 GSM
Printable version
of the leaflet.
Description
Microprocessor based THERMOMETER model KRT - 406 GSM
is a modern device designed to measure temperature even in four
different places and is also able to record measure result in
its internal, nonvolatile memory or print them on a portable printer PORTI
S30/40. Through RS-232 or RS-485 socket it can communicate with a PC computer.
RS-485 socket allows to connect up to 8 units of KRT - 406 GSM to only
one computer PC by a triple wire line.
Internal, nonvolatile, memory enable to record up to 50 000 records
at intervals ranging from 1 minute to 99 hours. Results recorded in the
internal memory might be transferred to th e computer PC directly connected
to the KRT - 406 GSM`s RS-232 output. In the field
operation, a portable, battery powered printer
can be directly connected to the KRT - 406 GSM thermometer. The
user can select chart or graphs printout using a thermohygrometer`s keyboard.
This sophisticated thermometer covers temperature range from -90oC
to +300oC with resolution
0.02oC.
Highier accuracies, grater than typical electronic thermometers are achieved
through a unique linearising technique.
Application of the internal microprocessor ensure a minimal measuring
error and a large alphanumeric easy-to read LCD display enable simply
read-out results. Nonvolatile memory stores setup conditions (RS-232,
log intervals, probes calibration etc) and also user's settings selected
from the keyboard. The meter also includes a real time clock which shows
time, day month and year. The meter accepts up to
four temperature probes with very long cables (up to
100 meters each).
The KRT -406 GSM features a quick disconnect panel input for all probes.
The model KRT - 406 GSM also contains visual alarms.
Simultaneous alarm points for temperature are user selectable. When the
current condition exceed any of the preset values, special icons on the
front panel lit.
This model also features the special port to connect the GSM modem
in order to sending the alarm SMSes
or current measurement results on even three mobile telephones
(on demand).
Easy routine maintance and small size provides an excellent comfort of
recording and wide application in scientific research, enviroment measurement,
food industry and many others.
Technical data:
Input : ................................................................
four or two Pt-100 temperature probes (4 wire)
Distance between probes and meter: ............................ up to
100 meters
Temperature probe calibration: ......................................
automatic matching at 0oC
Temperature measuring and logging range :...................................................
-90oC to +300oC
Resolution of current temperature : .................................................................
0,02oC
Accuracy of temperature measurement: .........................................................+
0,15 % of the range
Log interval: ........................ from 1 minute to 99 hours (programmable
through the meter`s keyboard)
Start/End of the logging: .......................................... through
the meter`s keyboard
Connection to PORTI S30/40 printer : ................ RS-232 port on the
KRT - 406 GSM housing
Communication with computer PC : .................... RS - 232 ( distance
to computer PC up to 4 meters)
industrial RS - 485 - special converter necessary - (distance from computer
PC up to 100 meters)
Temperature display: .......................................................
4 x 16 alphanumeric LCD display
Device status display: ........................................................
4 x 16 alphanumeric LCD display
Switching of measuring channels: ....................................
through meter`s keyboard
Data logging (programmable by the user):
1.storing in the nonvolatile, internal memory (up to 12 500 logs for each
channel) and further transferable to the PC and/or to the portable printer
with the time and date stamp as a chart or grahps
2.On-line output to the PC through RS-232 serial interface or RS-485 industrial
interface for further analysis, storage and hard copy printouts
Power: ....................................................................
9 V or 12V dc or 230 V ac through an adapter
Housing: ........................................................... black
plastic adapted to be hanged on a wall
Dimensions: .................................................L200 x H95
x D37 mm
Microprocessor based temperature dataloggers
Model KRT - 198
Geneza Ltd. 8-channel scanning
thermometers/loggers are perfect for simultaneous temperature monitoring during different
industrial and laboratory process steps.
Wall mount units in rugged plastic housing, which fulfil IP54 requirements, store data and
download to your PC or printer, because they feature RS 232 and Centronics parallel
printer output. Dependently from the model, this sophisticated thermometer covers
temperature range from -100oC to +1750oC
and achieve accuracies of +0.2% of reading. Reading may be logged and stored at
intervals ranging from 2 minutes to 99 hours. Nonvolatile memory stores setup conditions
(RS-232, printers, log interval, probe calibration). The meter also includes a real time
clock which shows time, day, month and year.
Higher accuracies, grater than the typical electronics HACCP, thermometers, are achieved through
a unique linearising technique. All models features a quick disconnect panel input
for probes and a large easy-to-read LED display allowing 0.1oC resolution for
Pt-100 probes and 1oC for thermocouples. However, if the meter is connected to
the PC you can achieve 0.01oC of resolution.
Common parameters:
Temperature display: ..................... 4 digit, red LED, 0.8 inch
Status display: ................................ 2 digit, green LED, 0.4
inch
Probe calibration: ........................... automatic matching at 0oC
Number of inputs: ........................... eight
Log interval: .................................... from 2 minutes to 99
hours (programmable)
Data logging:
- hard copy with the time and date on the printer connected to the
Centronics parallel printer output
- storing in the internal memory and further printing with the time and date
- output to the PC through RS - 232 serial interface for further analysis,
storage and hard copy printouts
Digital outputs: ................ RS - 232 serial interface and
Centronics parallel printer output
Power: ............................... 220 Volt, ac
Housing : .......................... wall mount, easy-to-view, drip proof
plastic housing
Model KRT - 198 version P
Temperature range: .................................................
-100oC
to +800oC
Resolution: ..............................................................
0.1oC
Input : .................................................... platinum Pt-100
probe ( 2 or 4 wire )
Model KRT - 198 version J
Temperature range : ............................................
0oC
to +750oC
Resolution: ............................................................ 1oC
Input : ....................................................................
Thermocouple type J
Model KRT - 198 version K
Temperature range : ............................................ 0oC
to 1250oC
Resolution : .......................................................... 1oC
Input : .....................................................
Thermocouple type K
Model KRT - 198 version S
Temperature range: .............................................
0oC to 1750oC
Resolution: .......................................................... 1oC
Input : ...................................................................
Thermocouple type S
Microprocessor based Thermometer/Datalogger
KRT 2002
Description:
Microprocessor based Geneza Ltd. Temperature logger KRT 2002 id (photo)
designed to precize mesurement and recording temperature in food, pharmaceutical
industry, fruits ripening tanks, cold stores (HACCP) and air conditioned
museums, banks and hospitals. Its easy toutine maintance and small size
provides an excellent comfort of recording and wide application in scientific
research and also in industry conditions. A device is equiped with
internal battery backup during power failure, so even if external power
failured recording is being continued.The logger is also equiped with
internal nonvolatile memory, enabling recording up to 70000 records. Results
recorded in internal memory might be transferred into computer or printed
on the computer printer directly connected to the KRT 2002 centronics
parallel printer output.
Computer temperature logger KRT-2002 collaborates with Pt-100 probes,
and with a computer by RS-232 or RS-485 socket. RS-485 socket allows to
connect up to 32 units of KRT 2002 to only one computer by a triple wire
line.
Application of the internal microprocessor ensure a minimal measuring
error and a large alphanumeric easy-to-read LCD display enables simple
read-out of results. Unique advantage of thermometer/logger is a possibility
of preprogrammed matching temperature characteristic of a probe applied
by User. Also using a 4 line probe wire allows to apply probes with very
long cable (up to 100 m). During the process of recording the thermometer
of the logger allows a read-out with 0.01oC resolution of the
actual temperature and also a minimal and maximal temperature, which
were in measuring area between switching on and off the logger.
Technical data
Temperature probe................................................................
Platinium Pt-100 RTD
Range of temperature measuring...................................... -50oC
to +160o C
Range between a logger and a probe................................. Up
to 100 m (4 wire line)
Way of connecting probe to logger......................................
4 wire
Resolution of actual temperature........................................
0.01 oC
Accurancy of temperature measure............................... 0.05 oC
of measuring range
Communication with a computer.. RS-232 socket (up to 3 m), RS-485 socket
(up to 100 m)
Log intervals...................................................... From
15 sec. To 99 hours
Archivization of results......................................................
Computer’s hard disk
Temperature read-out................................................ Alphanumeric
LED display
Power..................................................................................
220 V/ 9V dc
Operating humidity...............................................................
Up to 85% RH
Housing..................... Black plastic adapted to be hanged on a wall
Microprocessor based Thermometer/Datalogger
KRT 102
Description:
Microprocessor based Geneza Ltd. Temperature logger KRT-102 is designed to precize
measurement and recording temperature in food, pharmaceutical industry, fruits ripening
tanks, cold stores (HACCP) and air conditioned muzeums, banks and hospitals. Its easy
maintance and small size provides an excellent comfort of recording and wide application
in scientific research and also in industry conditions.
Microprocessor thermometer KRT 102 collaborates with Pt-100 probes, and with a computer
by RS-232 socket. Application of the internal microprocessor ensure a minimal measuring error and a large
alphanumeric easy-to-read LCD display enables saving the battery. Unique advantage of
the thermometer is a possibility of reprogrammed matching temperature characteristic of
a probe applied by User. Also using a 4 line probe wire allows to apply probes with very long conductor (up to 100 m)
During the process of recording the thermometer of the logger allows a read-out with
0.01oC resolution of the actual temperature and also a minimal and maximal temperature, which
were in measuring area between switching on and off the logger.
Technical data:
Temperature probe.......................................................... Platinium Pt-100 RTD
Range for temperature measuring..................................
-60oC to +200oC
Range between a logger and a probe............................. Up to 100m (4 wire line)
Way of connecting probe to logger.................................. 4 wire
Resolution of actual temperature....................................
0.01oC
Resolution of min/max temperature................................
0.01oC
Accurancy of temperature measure................................
0.05o
Communication with a computer..................................... RS-232 socket (up to 3 m)
Log intervals.................................................................... from 1 minute to 99 hours
Archivization of results..................................................... computer hard disk
Temperature read-out...................................................... Alphanumeric LED display
Power.............................................................................. 220 V/9 V dc
Operating humidity ......................................................... Up to 85% RH
Housing ........................................ Black plastic, adapted to be hanged
on the wall
Microprocessor Based
Thermometer/Datalogger Model TKP-302 Fl
Description
Geneza Ltd. TKP-302FL thermometer/loggers are perfect for temperature monitoring during carriage of
food products. The cap mount units in rugged plastic housing, store data and
download to your PC , because the feature RS-232 output. The TKP-302FL logger is also
equipped with internal nonvolatile memory enabling recording up to 50 000 records at intervals ranging from 1 minute to 99
hours. Results recorded in internal memory might be transferred into computer directly connected to the
TKP-302FL's RS-232 output. This sophisticated thermometer Covers temperature range from
-50oC to +200oC and achieve accuracy of + 0,1% of reading.
Nonvolatile memory stores setup conditions (RS-232, log interval, probe calibration). The meter also includes
a real time clock which shows time, day, month and year.
Higher accuracy, grater than the typical electronic HACCP
thermometers are achieved through a unique linearising technique. Application of the internal microprocessor ensure a minimal measuring error and a large alphanumeric
easy-to-read LCD display enable simply read-out of results. The meter accepts a 4 wire Pt-100 probe, which allows
to apply probes with very long cable (up to 100 meters).
TKP-302FL features a quick disconnect panel input for a probe. During the process of recording, the thermometer of the
logger allows read-out with 0.01oC resolution of the current temperature and also minimal and maximal temperatures,
which were in measuring area between switching on and off the meter.
Technical data
Input:
........................................................................ Platinum Pt-100 probe (4 wire)
Temperature range: ...................................................................
-50oC to +200oC
Distance between a logger and the probe : .............................. Up to 100 meters
Resolution of the current temperature: .....................................
0,01oC
Resolution of the min/max temperature: ...................................
0,01oC
Accuracy of temperature measurement: ................................... 0,1% of the range
Temperature display: ............................................ 4 x 16 alphanumeric LCD display
Probe calibration: .................................................. Automatic matching at
0oC
Log interval: ................................... from 1 minutes to 99 hours (programmable)
Data logging:
- storing in the internal memory and further transferable to the computer with the time and date as a chart of graphs
- output to the PC through RS - 232 serial interface for further analysis, storage and hard copy printouts
Digital outputs:............................................. RS-232 serial
interface output
Internal memory: ..................................................up to 50 000 records
Power:
.................................................................... 12 Volts dc
Housing: ...............black plastic housing adapted to be hang in the cap of the truck
Microprocessor Thermometer/logger TKP 202m
Description:
Microprocessor pocket thermometer TKP-202m is a hand meter designed to precize
measurment and recording temperature of constant bodies, liquids and gases. Its easy routine
maintance, small size and battery supply provides an excellent comfort of recording and wide
application in scientific research, ceramic industry, driers, textile, plastics and gum industry.
Microprocessor thermometer TKP-202m collaborates with Pt-100 probes. Application of internal
microprocessor ensure a minimal measuring error and a large alphanumeric easy-to-read LCD display
enables saving a battery. Unique advantage of a thermometer is a possibility of preprogrammed
matching temperature characteristic of a probe applied by User.
Also using a 4 line probe cable allows to apply probes with a long wire (up to several meters).
Thermometer allows a read-out of actual temperature and also a minimal and maximal temperature,
which were in measuring area between switching on and off the thermometer. It is also possible to
programm it by RS-232 socket from a computer, so it can record into its internal memory results of
measurment temperature in User marked time. After recording results of measurment gathered in
internal memory might be transferred into a computer’s hard disk.
Technical data
Temperature probe..........................................................
Platinium Pt-100 RTD
Way of connecting probe to thermometer........................ 4 wire
line
Resolution of actual temperature.....................................
0.01 oC
Resolution of min/max temperature................................. 0.01
oC
Accurancy of temperature measure.......... 0.05% of measuring range -50
oC to +150 oC
0.1% of measuring range +150 oC to +200 oC
Temperature read-out.......................................................
Alphanumeric LED display
Communication with a computer...................................... RS-232
socket (up to 3 m)
Internal memory (version FI)............................................
Up to 50000 readings
Microprocessor Based Thermometer/Datalogger
Model TKP- 402Fl
Description
The microprocessor based, pocket size thermometer model TKP-402 FL is (photo)
designed to precise measurement and recording temperature. Its easy routine
maintenance, small size and battery supply provides an excellent comfort
of ecording and wide application in scientific research, enviroment measurement,
food industry and many others.
The TKP - 402FL logger is also equiped with internal nonvolatile memory
enabling to record up to 50 000 records at intervals ranging from 1 minute
to 99 hours. Results recorded in the internal memory might be transferred
to the computer PC directly connected to the TKP - 402FL's RS-232 output.
In the field operation a portable, battery powered printer can be directly
connected to the TKP - 402FL thermometer. The user can select chart
or graphs printout using a thermometer's keyboard.
This sophisticated thermometer covers temperature range from
-60oC to +200oC
with resolution 0,01oC and achieve accuracies +0,05%
of the range. Highier accuracies, grater than typical electronic thermometers
are achieved through a unique linearising technique.
Application of the internal microprocessor ensure a minimal measuring
error and a large alphanumeric easy-to-read LCD display enable simply
read-out of results. Nonvolatile memory stores setup condtions (RS-232,
log interval, probe calibration) and also user's setting selected from
the keyboard. The meter also includes a real time clock which shows
time, day, month and year.
The meter accepts a 4 wire Pt - 100 probe, which allows to apply probes
with very long cable (up to 10 meters). The TKP - 402FL features a quick
disconnect panel input for a probe. During the process of recording, the
thermometer of the logger allows read-out with 0,01oC resolution
of the current temperature and also minimal and maximal temperatures that
were in measuring area between switching on and off the meter.
Technical data
Input: ...........................................................................
Platinum Pt - 100 probe (4 wire)
Temperature range: ......................................................
-60oC to +200oC
Resolution of current temperature: ..................................
0,01oC
Resolution of the min/max temperature: .......................... 0,01oC
Accuracy of temperature measurement: ....................... +
0,05% of the range
Temperature display:.....................................................
4 x 16 alphanumeric LCD display
Probe calibration: .......................................................
automatic matching at 0oC
Log interval: ........................ from 1 minute to 99 hours (programmable
through the meter's keybroad)
Start/End of the logging: .............................................through
the meter's keyboard
Data logging:
- storing in the nonvolatile, internal memory and further transferable
to the PC and/or to the portable printer with the time and date stamp
as a chart of graphs
- on-line output to the PC through RS-232 serial interface for further
analysis, storage and hard copy printouts
Digital output: ..............................................................
RS - 232 serial interface output
Internal memory: .........................................................
up to 50 000 records
Power:........................................................................
4 x 1,5 V batteries
Housing: ....................................................................
black plastic
Dimensions: ...............................................................
146 x 82 x 39 mm
Microprocessor Based Thermometer/Datalogger
Model KRT-2004
Description
The microprocessor based thermometer/logger model KRT-2004 (photo)
is designed to precise measurement and recording temperature.
Its easy routine maintenance and small size provides an excellent comfort
of recording and wide application in scientific research, enviroment measurement,
food industry, pharmaceutical industry and many others.
The KRT-2004 logger is also equiped with internal nonvolatile memory enabling
to record up to 50 000 records at intervals ranging from 1 minute to 99
hours. Results recorded in the internal memory might be transferred to
the computer PC or to the special memory reader model
UC-103 directly connected to the KRT-2004 logger's RS-232 output.
The KRT-2004 is perfect for temperature monitoring during carriage of
food products. The cap mount unit
in
rugged plastic housing store data and download to your PC. In the field
operation a portable, battery powered printer can be directly
connected to the KRT-2004 RS-232 output. The user can select
chart or or graphs printout using a thermometer's keyboard.
This sophisticated thermometer covers temperature range from -60oC
to +200oC with resolution 0,01oC
and
achieve accuracies + 0,05% of the range. Highier
accuracies, grater than typical electronic thermometers are achieved through
a unique linearising technique.
Application of the internal microprocessor ensure a minimal measuring
error and a large alphanumeric easy-to-read LCD display enables simply
read-out of results. Nonvolatile memory stores setup conditions (RS-232,
log interval, probe calibration) and also user's settings selected from
the keyboard. The meter also includes a real time clock which shows
time, day, month and a year.
The meter accepts a 4 wire Pt-100 probe, which allows to apply probes
with very long cable (up to 50meters).
The KRT-2004 features a quick disconnect panel input for a probe.
During the process of recording, the thermometer of the logger allows
read-out with 0,01oC resolution of
the current temperature and also minimal and maximal themperatures that
were in measuring area between switching on and off the meter.
Model KRT-2004 also contains two coloured LEDs, which lit in response
to an alarm condition. Alarm
points for high (red LED) and low (green LED) temperatures are user selectable.
When the current condition exceed any of the preset values special icons
on the front panel lit.
Technical data
Input: ......................................................................
Platinum Pt - 100 probe (4 wire)
Temperature range: .......................................................................
-60oC to +200oC
Resolution of current temperature: ....................................................................
0,01oC
Resolution of the min/max temperature: ...........................................................
0,01oC
Accuraccy of temperature measurement:.......................................................
+ 0,05% of the range
Temperature display:.......................................................................
4 x 16 alphanumeric LCD display
Probe calibration: ......................................................
automatic matching at 0oC
Log interval: ............................... from 1 minute to 99 hours
(programmable through the meter's keybroad)
Start/End of the logging: ............................................through
the meter's keyboard
Data logging:
- storing in the nonvolatile, internal memory and further transferable
to the PC and/or to the portable printer with the time and date stamp
as a chart of graphs
- on-line output to the PC through RS-232 serial interface for further
analysis, storage and hard copy printouts
Digital output: .........................................................
RS - 232 serial interface output
Internal memory: ...................................................................
up to 50 000 records
Alarms (programmable)...........................................................
green/red LEDs
Power:.............................................. 12Vdc or 220Vac through
an adaptor
Housing: .............................................................
black plastic
Dimension: ................................................................
165 x 95 x 40 mm
|| Main Page || Company
Profile || Offer || Products || Cooperation offer
|| Validation || Email ||
Leaflets/specifications: Hygromethers,
Thermometers (Dataloggers), Calibrators, Memory
readers Temperature Probes, Humidity & temperature probes, Manometers,
Temperature Loggers
Copyright © 1999-2004 PW Geneza Ltd. All rights reserved.
|