Temperature Measurement![]() ![]() |
|| Main Page || Company Profile || Offer || Products || Cooperation offer || Validation || Email || Leaflets/specifications: Hygromethers, Thermometers (Dataloggers), Calibrators, Memory readers Temperature Probes, Humidity & temperature probes, Manometers, Temperature Loggers Platinum Temperature Probe Description The TUL 1 industrial probe is designed for continously temperature monitoring and represent a major advance in precision temperature measurement. Probe assemblies are ideal for use in chemical processes, ovens, furnaces and vessels. Rugged construction withstands increased pressures and vibrational forces found in rough industrial enviroments. The TUL 1 as other Geneza Ltd. Platinum Resistance Probes are calibrated to the internationally accepted DIN IEC curve ( a = 0.00385) and meet 0.1% DIN standard tolerance. Hence, all our probes can be used interchangeable without meter recalibration. Also, the TUL 1 is compatible with a wide variety of microprocessor based and digital HACCP, thermometers, indicators, recorders and controlers designed for platinum resistance input. Specially Geneza Ltd. temperature measurement and control equipment are recommended. Probes are electrically isoleted and come with 1.2 meter lead. Water-resistant junction between probe and lead should not be immersed. Technical Data Description The M 10 x 1 industrial probe is designed for continously temperature monitoring and represent a major advance in precission temperature measurement. Probe assemblies are ideal for use in chemical processes, ovens, furnaces and vessels. Rugged construction withstands increased pressures and vibrational forces found in rough industrial enviroments. The M 10 x 1 as other Geneza Ltd. Platinum Resistance Probes are calibrated to the internationally accepted DIN IEC 750 curve ( a = 0.00385) and meet 0.1% DIN standard tolerance. Hence, all our probes can be used interchangeable without meter recalibration. Also, the M 10 x 1 is compatible with a wide variety of microprocessor and digital HACCP, thermometers, indicators, recorders and controllers designed for platinum resistance input. Specially Geneza Ltd. temperature measurement and control equipment are recommended. Probes are electrically isolated and come with 1.2 meter lead. Water -resistant junction between probe and lead should not be immersed. Technical Data
Description. The 1/4 inch industrial probe is designed for continously temperature monitoring and represent a major advance in precision temperature measurement. Probe assemblies are ideal for use in chemical processes, ovens, furnaces and vessels. Rugged construction withstands increased pressures and vibrational forces found in rough industrial enviroments. The G1/4 inch as other Geneza Ltd. Platinum Resistance Probes are calibrated to the internationally accepted DIN IEC curve ( a = 0.00385) and meet 0.1% DIN standard tolerance. Hence, all our probes can be used interchangeable without meter recalibration. Also, the G1/4 inch is compatible with a wide variety of microprocessor based and digital HACCP, thermometers, indicators, recorders and controlers designed for platinum resistance input. Specially Geneza Ltd. temperature measurement and control equipment are recommended. Probes are electrically isoleted and come with 1.2 meter lead. Water-resistant junction between probe and lead should not be immersed. Technical Data Description The G 1/2 inch industrial probe is designed for continously temperature monitoring and represent a major advance in precission temperature measurement. Probe assemblies are ideal for use in chemical processes, ovens, furnaces and vessels. Rugged construction withstands increased pressures and vibrational forces found in rough industrial enviroments. The G 1/2 inch as other Geneza Ltd. Platinum Resistance Probes are calibrated to the internationally accepted DIN IEC 750 curve ( a = 0.00385) and meet 0.1% DIN standard tolerance. Hence, all our probes can be used interchangeable without meter recalibration. Also, the G 1/2 inch is compatible with a wide variety of microprocessor and digital HACCP, thermometers, indicators, recorders and controllers designed for platinum resistance input. Specially Geneza Ltd. temperature measurement and control equipment are recommended. Probes are electrically isolated and come with 1.2 meter lead. Water -resistant junction between probe and lead should not be immersed. Technical Data Description The OS -130 research probe covers a broad range of applications including laboratory, industrial and warehouse, in food, grains and particles, in tank and narrow gaps, between sheets of paper and cloth, and for many applications in pharmacy, food processing or agriculture. Probe assemblies are also ideal for use in chemical processes,ovens, furnaces and vessels. The OS -130 as other Geneza Ltd. Platinum Resistance Probes are calibrated to the internationally accepted DIN IEC 750 curve ( a = 0.00385) and meet 0.1% DIN standard tolerance. Hence, all our probes can be used interchangeable without meter recalibration. Also, the OS -130 is compatible with a wide variety of microprocessor and digital HACCP, thermometers, indicators, recorders and controllers designed for platinum resistance input. Specially Geneza Ltd. pocket size digital or microprocessor thermometers are recommended. Probes are electrically isolated and come with 0.8 meter lead. Water -resistant junction between probe and lead should not be immersed. Technical Data
Description. The WG-130 laboratory and research probe is designed for continously temperature monitoring and represent a major advance in precission temperature measurement. Probe assemblies are ideal for use in chemical, processes,ovens, furnaces and vessels, soft material and molten plastic or rubber The WG-130 as other Geneza Ltd. Platinum Resistance Probes are calibrated to the internationally accepted DIN IEC 750 curve (a = 0.00385) and meet 0.1% DIN standard tolerance. Hence, all our probes can be used interchangeable without meter recalibration. Also, the WG-130 is compatible with a wide variety of microprocessor and digital HACCP, thermometers, indicators, recorders and controllers designed for platinum resistance input. Specially Geneza Ltd. pocket size digital or microprocessor thermometers are recommended. Probes are electrically isolated and come with 0.8 meter lead. Water -resistant junction between probe and lead should not be immersed. Technical Data
|| Main Page || Company
Profile || Offer || Products
|| Cooperation offer
|| Validation || Email
|| Copyright © 1999-2004 PW Geneza Ltd. All rights reserved. |